We assume no liability for safety, or responsibility for, the product's quality, performance or functionality should users. connected to the low-voltage installation. period. 1. 1. and General Specification: GS 05C01E81-11EN. The relative humidity is in accordance with the instrument. This action allows to put the instrument in a dened condition (the same it was at the rst power ON). The TC10 is a compact temperature single loop controller with easy -to-read 3 dynamic colors led display. Safety, Protection, and Modification of the Product, - In order to protect the system controlled by this product and the, product itself, and to ensure safe operation, observe the safety, precautions described in the Engineering manual. Use of the in-, strument in a manner not prescribed herein may compromise the, product's functions and the protection features inherent in the, device. The relative humidity is in accordance with the instrument, The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - Digital Input (DI2) connecting a free of. use only, in an electrical panel which encloses the rear housing. Allows to increase the value of the selected parameter. 1.Push the button for more than 3 seconds. Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals), Universal input: (TC, mV, V, mA, Pt100-Pt1000), Easy User Control for high limit or low limit, Timer (Counts the total time the setpoint is exceeded), Register to retain the maximum temperature reached, Serial communication: RS-485 Modbus (optional), IP65 front panel (when the optional panel gasket is mounted)(optional), Universal Input: TC, mV, V, mA, Pt100, Pt1000, Power consumption: 6.0 VA max. : set points, proportional band, etc.). Note: For TC wiring use proper compensating cable preferable shielded. 7. terminal 1 and 2 to transmitter signal output. Backed by the high reliability and quality that Yokogawa has cultivated over many years. TC10-L is a panel mounting, Class II instrument. The short depth of the controller helps save instrument panel space. The relative humidity is in accordance with the instrument, The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the. What is the measured current of the TC10's RTD input? Also, YOKOGAWA Electric Corporation assumes no liability for the customer's, failure to comply with these requirements. - As a safety measure, always install a circuit breaker (an IEC 60947, compatible product, 5 A, 100 V or 220 V AC) in an easily accessible, location near the instrument. Set detailed parameter out group o1.F (output 1 function) = r.inP. any latin characters (a-z, A-Z) any numbers (0-9) special characters ("-", "_" and ". I selected SP value transmission on TC10, but no SP value is displayed. If applicable, a timer count control monitors the amount of time outside the setpoint and registers the maximum temperature reached. IP65 rated as "dust tight" and protected against water projected from a nozzle when the optional panel gasket is mounted (for indoor locations) according to EN 60070-1. - For control relay output, alarm relay output, and power terminal, -N o C o o o D o F Temperature Controller, The TC10-N can be easily configured by the "Code Configuration" method for the most common requirements, just entering two 4-digit. Current availability for non-stock parts is "Usually ships in 7-10 business days". Use a tester or similar device to ensure. The cable length must not exceed 1.5 km at 9600 baud. No. D + D - D + D - D + D - D + D - RS-485 5 6 The UT52A/MDL supports 920 MHz band wireless communication. YOKOGAWA Accessory Manuals 12 Devices / 14 Documents Full list of YOKOGAWA Accessory Manuals YOKOGAWA AC Power Distribution Manuals 1 Devices / 1 Documents YOKOGAWA Adapter Manuals 9 Devices / 10 Documents The UT32A-V,-C,-R is an easily configurable single-loop controller for 1/8 DIN sized. Installation altitude: less than 2000 m; The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. (63% response when the input changes from 10% 90%). [3] SSc - Initial scale read-out for linear inputs. The readout is updated every 15 minutes. that no power is being supplied to a cable to be connected. In other words the upper display will show: ]INP. It has been de-, signed with compliance to the European Directives. future reference. Yokogawa TC10-L Temperature Controller Datasheet PDF, Yokogawa TC10-L Limit Controller Quick Reference Guide, Yokogawa TC10-L Temperature Controller Manual PDF, Yokogawa TC10-L Temperature Controller Brochure PDF, Yokogawa UT150L to TC10-L Cross Reference Guide PDF, Universal Input: (TC, mV, V, mA, Pt100-Pt1000), Limit control function (High limit / Low limit), Includes one digital input for external limit reset. 3. 1. Wattmeter Instantaneous power is continuously computed, as multiplication of the Load Voltage, Load Current parameter. A short press allows to exit from the current parameter group and select a new parameter group. However, the instrument will only show the parameters applicable to its hardware options in accordance with the specic instrument conguration (i.e. 2.56 in min. SSR outputs are not isolated. Note: The complete list of the default parameters is available in Appendix A. Category: Controller. All information about the controller use can be found in the Engineering Manual: - IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN and General Specification: GS 05C01E81-01EN. The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the maximum temperature reached. The Yokogawa TC10-L is an all-in-one, FM approved limit controller with an easy-to-read, 3-color LED display. 18 months (a year and a half) after shipment from the factory. Fsc allows the scaling of the analog input to set the maximum displayed/measured value. 2.Using and buttons set the programmed password. When a shielded cable is used, it should be connected at, 4. It also includes a ladder sequence function. If the password is correct the display will show the acronym of the rst parameter group preceded by the symbol: ]. The Yokogawa TC10-L is an all-in-one, FM approved limit controller with an easy-to-read, 3-color LED display. The UT75A also support open networks such as Ethernet communication. [13] AL1 and [30] AL2 will be forced to : for an absolute maximum alarm, them will be forced to the maximum input span, for an absolute minimum alarm, them will be forced to the minimum input span, for all other alarm, them will be forced to zero, [14] HAL1 and [31] HAL2 will be forced equal to the 0.5% of the input span, [35] HYS will be forced equal to 0.05 % of the input span, the CAL group will be reset [51]A.L.P, [52] A.L.O, [53] A.H.P, [54] A.H.O, Upload manuals that we do not have and get. If thePV does not exceed SP, after the conrming operation, output relay will be energized (closed) and the output (OUT) display lamp turns off . External components (like zener barriers, etc.) RS-485 interface allows to connect up to 30 devices with one remote master unit. Can I turn off the "C" display with input other than temperature on TC10? What is the /GK suffix code for the TC10? - Installation of protection and/or safety circuits with respect to a, lightning protector; protective equipment for the system controlled, by the product and the product itself; foolproof or failsafe design, of a process or line using the system controlled by the product or, the product itself; and/or the design and installation of other, protective and safety circuits are to be appropriately implemented, Note: To leave the Configuration session without, - This product is not designed or manufactured to be used in critical, applications that directly affect or threaten human lives. : control, alarms, output functions). The TC10 supports easy configuration with codes for quick start-up. 5.3 HOW TO ENTER THE CONFIGURATION MODES. use only, in an electrical panel which encloses the rear housing. : input type, Control strategy, alarms, etc.). The factory default password for conguration parameters is equal to 30. The relative humidity is in accordance with the instrument, The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - Digital Input (DI2) connecting a free of. View online (2 pages) or download PDF (1 MB) YOKOGAWA TC10 User manual TC10 measuring, testing & control PDF manual download and more YOKOGAWA online manuals Select a mounting location having the following characteristics: 2. Can I hide the SP display? The TC10L features universal - input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the The ambient temperature is in accordance with the operative, 6. exposed terminals and wiring on the back. What is the I/O response time of the TC10? voltage contact between terminals 4 and 16; - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. The TC10 is a compact single loop temperature controller with an easy-to-read 3-color LED display. Related Manuals for YOKOGAWA TC10-L . Note: For TC and RTD inputs the decimal figure must be 0 or 1 only. connected between sensor and input terminals may cause errors in measurement due to excessive and/or not balanced line resistance or possible leakage currents. YOKOGAWA Manuals and User Guides All-Guides Database contains 857 YOKOGAWA Manuals (1264 Devices) for Free Downloading (PDF). The TC10 supports easy configuration for quick start-up, and itsPID allows for overshoot andundershoot control, so the end user can maintain a direct and constant temperature or accurate flow. If this instrument is used in a manner not specified in this manual. There are no water or other fluids (i.e. Calibration: According to EN 60751/A2. Are the TC10s wiring terminals screw terminals? fail to observe these instructions when operating the product. The Yokogawa TC10-L limit controller is an FM-approved limit controller that can be configured either as a high limit or as a low limit controller by a user. On the TC10, I want the difference lower limit alarm to be ON 5C below the setpoint value. Pay attention to the line resistance; a high line resistance may cause measurement errors. 2.The cable length must not exceed 1.5 km at 9600 baud. Input circuit: Current injection (135 A). There's no SG terminal for wiring RS485 communication on the TC1. In the following pages we will describe all the parameters of the instrument. Model TC10 Temperature Controller, Quick Guide, Model TC10 Temperature Controller, Engineering Manual, Model TC10 Temperature Controller, Serial communication protocol Modbus for TC10, New Legislative Framework (NLF) Conforming Products, List of RoHS (2011/65/EU) Directive Compliant Products (6-substances RoHS compliant products), Replacement Guide for TC10 Temperature Controller, The EU Declaration of Conformity TC10 *Log-in Required, Temperature Controllers 2D CAD *Log-in Required, Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals), Universal input: (TC, mV, V, mA, Pt100-Pt1000), IP65 front panel (when the optional panel gasket is mounted)(optional). Input impedance:> 1 M. V output: 0/2 10 V, galvanically isolated, RL min. I selected SP value transmission on TC10, but no SP value is displayed. 1. There is minimum vibrations and no impact; 4. Notes: 1. 1 digit @ 25C of room temperature; Electromagnetic compatibility and safety requirements. - Install the power cable keeping a distance of more than 1 cm from, - The power cable is required to meet the IEC standards concerned or the. 2. condensation); 5. The EU Declaration of Conformity and the manual of the controller. - As a safety measure, always install a circuit breaker (an IEC 60947, compatible product, 5 A, 100 V or 220 V AC) in an easily accessible, location near the instrument. Note: Before starting the configuration code setting, please define and write down Cod1 and Cod2 as needed: Linear 0 to 20 mA (this selection forces Out 4 = TX), Linear 4 to 20 mA (this selection forces Out 4 = TX), Note: As default, when the alarms are active, only AL1 threshold, is available at "Operator Command" level to perform non, critical tasks. Do not run logic input wiring together with power cables; The instrument needs 150 ms to recognize a contact status variation; To avoid electrical shocks, connect power line at last. Search the full list . Can I hide the SP display? Id like to confirm the parameters that can be set for TC10 RS485 communication setting criteria (protocol, baud rate, parity, stop bit, data length). - Modification of the product is strictly prohibited. 16 AWG or larger wires rated for at last 75C. The upper display will show PASS while the lower display will show 0. Model: digitalview ALR-1400, digitalview 417100041-3. voltage contact between terminals 4 and 16; - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. Clamp meters can perform analyses in the field on live conductors without interrupting the circuit. Set detailed parameter out group o1.F (output 1 function) = r.inP. CONTROLLER Engineering Manual. For SSR, mA and V outputs if the line length is longer than 30 m use a shielded wire. To load the factory default parameter set, proceed as follows: 1.Press the button for more than 5 seconds. The instrument have one complete parameter set. The Yokogawa TC10-L is an all-in-one, FM approved limit controller with an easy-to-read, 3-color LED display. Do not use it, for measurements in locations falling under Measurement Catego-, For measurements performed on circuits not directly, For measurements performed on circuits directly. a change of the parameters related with it (e.g. - As a safety measure, always install a circuit breaker (an IEC 60947, compatible product, 5 A, 100 V or 220 V AC) in an easily accessible, location near the instrument. connected, between sensor and input terminals may cause errors in, measurement due to excessive and/or not balanced line, 3. Range: 0 to 3 when [1] SenS = Linear input; 0 or 1 when [1] SenS different from linear input. Backed by the high reliability and quality that Yokogawa has cultivated over many years. Copyright 1994-2023 Yokogawa Electric Corporation, {{ baseCtrl.fullNavList[baseCtrl.fullNavList[baseCtrl.currentMenuDepth].parent].name }}, {{ baseCtrl.fullNavList[baseCtrl.currentMenuDepth].name }}, Special Solutions of OpreX Transformation, Visual MESA Supply Chain Scheduling (VM-SCS), Visual MESA Production Accounting (VM-PA), Cloud Inventory Management Solutions (Web*VMI), Platform for Advanced Control and Estimation (Advanced Process Control), OpreX Laboratory Information Management System, Remote Plant Performance Operation and Remote Consulting (KBC Co-Pilot Program), Predictive Maintenance of Pump Cavitation, Advanced Analytical Instrument Management System (AMADAS), FluidCom Chemical Injection Flow Controller, Real-time Plant Data Sharing Service (Web*Technician), Digital Plant Operation Intelligence (DPI) Quality Stabilization System, OpreX Data Model Broker / Design Data Validation, OpreX Customer Service Management Software, OpreX IT/OT Security Operations Center (SOC), Plant Information Management System (Exaquantum), Alarm Reporting and Analytics (Exaquantum/ARA), Integrated Production Information (Exaquantum/mPower), Power Performance Calculations (Exaquantum/PPC), Safety Function Monitoring (Exaquantum/SFM), Operator Trending Module (Exaquantum/OTM), Remote Data Synchronization (Exaquantum/RDS), Synchronous OPC DA Manager (Exaquantum/SDM), Manufacturing Data Exchange (Exaquantum/MDX), Public announcement of Yokogawas products, Single-Cell Analysis Solution Single Cellome, Distributed Temperature Sensor - Fire Detection/Fire Prevention -, Industry and Interface Libraries (Applications and Interfaces), Advanced Control Bioreactor System BR1000, ALH for FlowCam: Automated Liquid Handling, Yokogawa announcement to Windows XP users regarding Systems products, A Business Value Decision ofImpact and Significance, Yokogawa Cloud IT/OT Connectors & Integrations, TC10-L Temperature Controller Limit Control Type Engineering Manual, TC10-L Temperature Controller Limit Control Type Serial communicaiton protocol, TC10-L Temperature Controller (Limit Control Type), Model TC10-L Temperature Controller (Limit Control Type), Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals), Universal input: (TC, mV, V, mA, Pt100-Pt1000), Limit control function (High limit / Low limit), IP65 front panel (when the optional panel gasket is mounted)(optional). that no power is being supplied to a cable to be connected. The 3-year warranty extends 36 months after shipment from our factory. The UT35A and UT32A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. Can't find your region? The following symbol is, This manual is an essential part of the product; keep it in a safe place for. AL on the front of the TC10 is the alarm lamp. The shallow depth of the controller helps to save instrument panel space. Approximately 2 seconds or less. Moreover, provide indication that the. {{ baseCtrl.fullNavList[baseCtrl.fullNavList[baseCtrl.currentMenuDepth].parent].name }}, {{ baseCtrl.fullNavList[baseCtrl.currentMenuDepth].name }}, Floating Production Storage & Offloading (FPSO), Special Solutions of OpreX Transformation, Terminal Logistics Suite VP (Terminal Automation), Visual MESA Supply Chain Scheduling (VM-SCS), Cloud Inventory Management Solutions (Web*VMI), Platform for Advanced Control and Estimation (Advanced Process Control), OpreX Laboratory Information Management System, Remote Plant Performance Operation and Remote Consulting (KBC Co-Pilot Program), Mobile Field Device Management (FieldMate), Predictive Maintenance of Pump Cavitation, Advanced Analytical Instrument Management System (AMADAS), FluidCom Chemical Injection Flow Controller, Real-time Plant Data Sharing Service (Web*Technician), OpreX Data Model Broker / Design Data Validation, OpreX IT/OT Security Operations Center (SOC), Plant Information Management System (Exaquantum), Alarm Reporting and Analytics (Exaquantum/ARA), Integrated Production Information (Exaquantum/mPower), Power Performance Calculations (Exaquantum/PPC), Safety Function Monitoring (Exaquantum/SFM), Operator Trending Module (Exaquantum/OTM), Remote Data Synchronization (Exaquantum/RDS), Synchronous OPC DA Manager (Exaquantum/SDM), Manufacturing Data Exchange (Exaquantum/MDX), Public announcement of Yokogawas products, Distributed Fiber Optic Temperature Sensor, Industry and Interface Libraries (Applications and Interfaces), Yokogawa Pre-Engineered Analyzer Solutions - YES, Loading, Metering and Blending Automation, Plant Annunciator and SOE Recording System, Transmitterless SENCOMSMART Sensor Platform, Advanced Control Bioreactor System BR1000, Yokogawa announcement to Windows XP users regarding Systems products, A Business Value Decision ofImpact and Significance, Yokogawa Cloud IT/OT Connectors & Integrations, Support Information - New Legislative Framework (NLF) Conforming Products, Temperature Control for Seal-heating Parts in Wrapping Machinery. terminal 1 and 2 to transmitter signal output. displayed value becomes 999.9C or 999.9F. For different configurations, see, Wattmeter (instantaneous power expressed in kW) (note 1), Wattmeter (Power consuption expressed in kWh/h) (note 2), Absolute worked time (expressed in days) (note 3), Absolute worked time (expressed in hours) (note 3), Notes: 1. Before connecting the output actuators, we recommend to congure the parameters to suit your application (e.g. [13] AL1 and [30] AL2 will be forced to : for an absolute maximum alarm, them will be forced to the maximum input span, for an absolute minimum alarm, them will be forced to the minimum input span, for all other alarm, them will be forced to zero, [14] HAL1 and [31] HAL2 will be forced equal to the 0.5% of the input span, [35] HYS will be forced equal to 0.05 % of the input span, the CAL group will be reset [51]A.L.P, [52] A.L.O, [53] A.H.P, [54] A.H.O. 1. Can't find your region? A reinforced isolation must be assured by the external solid state relays. There is minimum vibrations and no impact; 4. condensation); 5. Such, applications include nuclear power equipment, devices using, radioactivity, railway facilities, aviation equipment, air navigation. ), Panel cutout: 45[-0, +0.6] x 45[-0, +0.6] mm (1.78[- 0.000, +0.023] x 1.78[- 0.000, +0.023] in.). Assign OP4 to the control output operation. Select a mounting location having the following characteristics: 2. The readout is updated every 15 minutes. about the controller use can be found in the Engineering Manual: IM 05C01E81-12EN and the Communication Manual: IM 05C01E81-13EN. The UT35A/UT32A also support open networks such as Ethernet communication. 1.Do not run input wires together with power cables. When the maximum front protection (IP65) is. Worked Time counter is continuously increased when, Overall dimensions (L x H x D): 48 x 48 x 73 mm, This instrument is intended for permanent installation, for indoor. When a TC input is selected and a decimal gure is programmed (see the next parameter) the max. All information about. The equipment wholly protected by double insulation or, - Whenever a failure or a malfunction of the device may cause dan-, gerous situations for persons, things or animals, please remember, that the plant must be equipped with additional devices which, - We warrant that the products will be free from defects in material. A ladder sequence function is included as standard. Search the full list . ]inP Group - Main and auxiliary input conguration. 2. suit your application (e.g. The UT75A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. There is minimum vibrations and no impact; There are no water or other uids (i.e. Use a tester or similar device to ensure. Safety, Protection and Modification of the Product, - In order to protect the system controlled by this product and the, product itself, and to ensure safe operation, observe the safety, precautions described in the Engineering manual. I want to use it as a display. Brand: YOKOGAWA . Nadcap AMS2750F - What's New and How to Comply? If so used, it is the user's responsibility to include in the system additional. Note: This filter will affect the measured value but also the control action the analogue retransmission and the alarms, Overall dimensions (L x H x D): 48 x 48 x 73 mm, This instrument is intended for permanent installation, for indoor. When using an external power supply with 2-wire wiring of TC10, what is the input resistance when inputting 4-20 mA? The following symbol is, This manual is an essential part of the product; keep it in a safe place for. The Yokogawa TC10-L limit controller is an FM-approved limit controller that can be configured either as a high limit or as a low limit controller by a user. terminal 1 and 2 to transmitter signal output. The EU Declaration of Conformity and the manual of the controller. "), 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan www.yokogawa.com/ns. fail to observe these instructions when operating the product. For measurements performed in the building instal-, For measurements performed at the source of the, - Wiring work must be carried out by a person with basic electrical, - Be sure to turn OFF the power supply to the controller before wiring, to avoid an electric shock. At this point you can set the operator. The SP value is not displayed if you dont specify a control operation. The conguration parameters are collected in various groups. For complete controller configuration see the Engineering Manual. This manual is intended for the following personnel: - Engineers responsible for installation, wiring, and maintenance of, - Personnel responsible for normal daily operation of the equip-, Calls attention to actions or conditions that could cause serious or, fatal injury to the user or damage to the instrument, and indicates, precautions that should be taken to prevent such occurrences. - Wiring should be installed to conform to NEC (National Electrical, Code: ANSI/NFPA-70) or the wiring construction standards in. Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. {{ baseCtrl.fullNavList[baseCtrl.fullNavList[baseCtrl.currentMenuDepth].parent].name }}, {{ baseCtrl.fullNavList[baseCtrl.currentMenuDepth].name }}, Special Solutions of OpreX Transformation, Visual MESA Supply Chain Scheduling (VM-SCS), Visual MESA Production Accounting (VM-PA), Cloud Inventory Management Solutions (Web*VMI), Platform for Advanced Control and Estimation (Advanced Process Control), OpreX Laboratory Information Management System, Remote Plant Performance Operation and Remote Consulting (KBC Co-Pilot Program), Predictive Maintenance of Pump Cavitation, Advanced Analytical Instrument Management System (AMADAS), FluidCom Chemical Injection Flow Controller, Real-time Plant Data Sharing Service (Web*Technician), Digital Plant Operation Intelligence (DPI) Quality Stabilization System, OpreX Data Model Broker / Design Data Validation, OpreX Customer Service Management Software, OpreX IT/OT Security Operations Center (SOC), Plant Information Management System (Exaquantum), Alarm Reporting and Analytics (Exaquantum/ARA), Integrated Production Information (Exaquantum/mPower), Power Performance Calculations (Exaquantum/PPC), Safety Function Monitoring (Exaquantum/SFM), Operator Trending Module (Exaquantum/OTM), Remote Data Synchronization (Exaquantum/RDS), Synchronous OPC DA Manager (Exaquantum/SDM), Manufacturing Data Exchange (Exaquantum/MDX), Public announcement of Yokogawas products, Single-Cell Analysis Solution Single Cellome, Distributed Temperature Sensor - Fire Detection/Fire Prevention -, Industry and Interface Libraries (Applications and Interfaces), Advanced Control Bioreactor System BR1000, ALH for FlowCam: Automated Liquid Handling, Yokogawa announcement to Windows XP users regarding Systems products, A Business Value Decision ofImpact and Significance, Yokogawa Cloud IT/OT Connectors & Integrations, Support InformationNew Legislative Framework (NLF) Conforming Products, Temperature Control for Seal-heating Parts in Wrapping Machinery. values and the controller output instantaneous value. condensation); 5. (100 to 240 VAC), Insulation voltage: 2300 V rms according to EN 61010-1, Front protection: IP 65 (when the optional panel gasket is mounted), Accessories: Mounting bracket, Quick Guide, Operative Modes: Auto / Manual / Stand-by (force control output to zero), Serial Communication (optional): RS-485 MODBUS, PID control with single or double action with overshoot control (Fuzzy overshoot control), ON/OFF, ON/OFF Neutral Zone, Auto-tuning, and Self-tuning. The UT55A and UT52A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. 2.56 in min. The shallow depth of the controller helps to save instrument panel space.
yokogawa tc10 l manual